Čisté nástavce s vysoce účinným filtrem

Product selection A-Z
Productname
layer

TFEA

Ceiling diffuser for extract air applications
  • Use in medicine, biology, pharmacy and sensitive areas of technology
  • Various diffusers to ideally meet individual requirements
  • Compact design, suitable for connection to commercially available cleanroom ceiling systems
  • Integrated filter holder, connection option horizontal (round, square) or vertical (round)
  • For cleanroom classes 5 - 8 according to EN ISO 14644-1
  • Meets the hygiene requirements of VDI 6022
  • Leakage class: EN 1886 L1, EN 15727 class D

další informace

layer

TFC

Ceiling mounted particulate filters as a final filter stage with Mini Pleat filter panels for the separation of suspended particles. Used in medicine, biology, the pharmaceuticals industry, and sensitive technical areas.

  • Easy, time-saving and secure filter change, can be completed by one person due to special press-in frame
  • Quick and easy diffuser fixing with central screw and spring
  • Robust, welded construction
  • With or without optional sealing integrity test facility
  • Compact construction, suitable for low ceilings, integration with all clean room ceiling systems from various manufacturers
  • Various diffusers to ideally meet individual requirements
  • Horizontal (circular, rectangular) or vertical (circular) connection
  • Choice of low-leakage shut-off damper or volume flow limiter for horizontal connection
  • Equipment for differential pressure measurement and particle sampling for measurements
  • Filter element can be easily accessed from the clean air side even after installation thanks to a removable cross bar
  • For air cleanliness classes 5 to 8 according to ISO 14644-1
  • Meets the hygiene requirements of VDI 6022
  • Leakage class: EN 1886 L1, EN 15727 class D

další informace

layer

TFW

Wall mounted particulate filters as a final filter stage with Mini Pleat filter panels for the separation of suspended particles. Used in medicine, biology, the pharmaceuticals industry, and sensitive technical areas.

  • Easy, time-saving and secure filter change, can be completed by one person due to special press-in frame
  • For air cleanliness classes 5 to 8 according to ISO 14644-1
  • Different constructions for filter elements with various frame depths
  • Casing with indentations to ensure the precise fitting of the filter elements
  • Equipment for differential pressure measurement, sealing integrity testing, and particle sampling for measurement
  • Meets the hygiene requirements of VDI 6022

další informace

layer

TFP


 

Pharmaceutical clean room terminal filters as a final filter stage with Mini Pleat filter panels for the separation of suspended particles. Used in highly sensitive areas in pharmaceuticals, medicine, and biology

  • Mini Pleat filter panels with downstream fluid seals meet the highest hygiene requirements
  • Easy, time-saving, and secure filter change
  • Air terminal device is held in place by magnets and can be hinged down to facilitate cleaning and validation; filter change with patented turn clip
  • Newly designed supports for mounting in false ceilings
  • Robust, welded construction
  • Compact construction, suitable for low ceilings
  • Various diffuser face plates to ideally meet individual requirements
  • Horizontal or vertical connection
  • Removable spigot for installation into closed ceilings in case of horizontal connection
  • For air cleanliness classes 5 to 8 according to ISO 14644-1
  • Meets the hygiene requirements of VDI 6022

 

 

 


další informace

layer

TFM


Particulate filter modules for ceilings as a final filter stage with Mini Pleat filter panels for the separation of suspended particles. Use in laboratories, medical areas, or production rooms in the pharmaceutical and food industries.

  • Individual casings can be combined modularly to form ceiling tiles
  • Easy, time-saving, and secure filter change due to special press-in frame
  • For mounting filters with flat or fluid seal
  • With sealing integrity test facility for filter elements
  • Integrated differential pressure measuring points
  • Internal measuring tube to sample particles for measurement
  • Spigot with lip seal
  • Flexible suspension
  • For air cleanliness classes 5 to 8 according to ISO 14644-1
  • Meets the hygiene requirements of VDI 6022
  • Leakage classes: L1 according to DIN EN 1886 and D according to DIN EN 15727

další informace

production {"X-Frame-Options"=>"SAMEORIGIN", "X-XSS-Protection"=>"1; mode=block", "X-Content-Type-Options"=>"nosniff", "X-Download-Options"=>"noopen", "X-Permitted-Cross-Domain-Policies"=>"none", "Referrer-Policy"=>"strict-origin-when-cross-origin", "Strict-Transport-Security"=>"max-age=31536000; includeSubDomains", "Content-Type"=>"text/html; charset=utf-8"}

Sdílet stránku

Doporučit tuto stránku

Doporučit tuto stránku zasláním odkazu emailem.

Pole označená (*) jsou povinná.

Sdílet stránku

Děkujeme za doporučení!

Vaše doporučení bylo odesláno a zakrátko by mělo být doručeno.


Kontakt

Jsme tu pro vás

Uveďte prosím své sdělení a druh dotazu
Tel.: +420 283 880 380 | Fax: +420 286 881 870

Attachment (max. 10MB)

Pole označená (*) jsou povinná.

Kontakt

Děkujeme vám za zprávu!

Vaše zpráva je odeslána a zakrátko bude zpracována.
Naše oddělení pro servisní dotazy se s vámi co nejrychleji spojí Pro obecné informace o výrobcích nebo o službách můžete také zavolat:
Tel.: +420 283 880 380 | Fax: +420 286 881 870

Kontakt

Jsme tu pro vás

Uveďte prosím své sdělení a druh dotazu