DID-E2_4L_img_05
DID-E2
Water connections with control components
DID-E2 without accessories and useful additions
Front view with nozzles
Induced air grille and supply air grille from the TROX grille range
Eurovent certification
DID-E2_4L_img_05

DID-E2 

ACTIVE CHILLED BEAMS WITH ONE WAY AIR DISCHARGE AS A QUIET ALTERNATIVE TO FAN COIL UNITS WITH TWO HORIZONTAL HEAT EXCHANGERS VARIANTS FOR DIFFERENT OUTPUT RANGES

Active chilled beams for heating and cooling with 2- or 4-pipe heat exchangers for installation in ceiling bulkheads, e.g. in hotel rooms and hospital wards in the nominal lengths of 1000, 1125 and 1250 mm

  • Preferably for room heights up to 4.00 m
  • High heating and cooling capacity with a low conditioned primary air volume flow rate and low sound power level
  • Media supply on the reverse or from the corridor side
  • Compact device dimensions oriented to the basic dimensions and 2 different widths or depths for the heat exchanger to cover different output ranges
  • Fixing points for various types of suspension systems/points
  • Combination with different control systems, e.g. X-AIRCONTROL or control air-water systems possible

Optional equipment and accessories

  • Integrated volume flow controller
  • Standard grilles from the TROX grill range
  • Various water connections, smooth CU tube, external thread G1/2" and flat seal or union nut G1/2" and flat seal
  • The supply air spigot is extendable to compensate for structural tolerances

APPLICATION

Application

  • Active chilled beams of Type DID-E2 for installation into ceiling bulkheads, preferably for room heights of up to 4.00 m

  • Especially for hotel rooms and hospital wards
  • Load removal with water enables a reduction of the primary air flow rate to the required minimum fresh air flow rate

  • 2-pipe or 4-pipe heat exchangers enable good comfort levels with a low conditioned primary air volume flow rate

  • Energy-efficient solution since water is used for heating and cooling


Special features

  • One-way air discharge
  • Horizontal heat exchanger as 2-pipe or 4-pipe system

  • The connection points are at the back of the unit, which is typically connected from the corridor

  • The supply air spigot is extendable to compensate for structural tolerances

  • Nominal sizes are based on the basic dimensions
  • Integral volume flow controller as an option

Nominal sizes

  • 1000, 1125, 1250 mm

DESCRIPTION

Variants

Water connection

    • Position right (-R) or left (-L)
    • Smooth copper tube Ø12 mm
    • A1: external thread ½” with flat seal
    • A2: union nut½” with flat seal


Heat exchanger

  • 2: 2-pipe systems
  • 4: 4-pipe systems


Nozzle variants

  • HE: small
  • S1: medium
  • S2: large
  • HP: extra large
  • H2: nozzle mix (50 % S2 nozzle and 50 % HP nozzle)


Other nozzle mixes possible on request.

Attachments

  • VC: Integrated flow rate control subassembly

Accessories

  • Z: Extension spigot for the supply air (if a supply air grille with concealed screw fixing is used, the extension spigot for supply air is essential)

  • ERS: Installation subframe for secondary air grille


Useful additions

  • Connecting hoses, type FS
  • LWS control equipment consisting of a control panel with integral room temperature sensor including controller, valves and valve actuators; and lockshields

  • Grille for supply air and secondary air from the TROX grill range

  • Control system X-AIRCONTROL for water-side and air-side control with the option of a connection to the central BMS

  • For further information on the X-AIRCONTROL and for information relevant to design, please refer to the installation and operating manual


Construction features

  • Spigot is suitable for circular ducts to EN 1506 or EN 13180

  • 5 nozzle variants for needs-based, optimum induction

  • Side-mounted bracket for attachment with various mounting systems

  • A mixture of nozzles is possible
  • Devices without flow rate control subassembly have a central primary air connection, devices with a flow rate subassembly have a primary air connection on the left or right


Materials and surfaces

  • Casing, nozzle plate, supply air spigot and installation subframe for secondary air grille made of galvanised sheet steel

  • Heat exchanger with copper tubes and aluminium fins

  • Surface of the casing and heat exchanger optionally available in black (RAL 9005)


Standards and guidelines

  • Products are certified by Eurovent (no. 09.12.432) and listed on the Eurovent website

  • Declaration of hygiene conformity to VDI 6022
  • Sound power level of the air-regenerated noise measured according to EN ISO 5135


Maintenance

  • Variants without flow rate control subassembly (VC) are low-maintenance, as there are no moving parts. The flow rate control subassembly can be accessed via a separate casing cover for maintenance purposes

  • The heat exchanger can be vacuumed with an industrial vacuum cleaner if necessary

  • VDI 6022, Part 1, applies (hygiene requirements for ventilation and air conditioning systems)


Technické údaje

Function, Technical data, Quick sizing, Specification text, Order code, Related products

  • FUNCTION
  • TECHNICAL DATA
  • QUICK SIZING
  • SPECIFICATION TEXT
  • ORDER CODE

Functional description

Active chilled beams provide centrally conditioned primary air (fresh air) to the room and use heat exchangers for additional cooling and/or heating.

The primary air is discharged through nozzles into the mixing chamber; as a result of this, secondary air (room air) is induced via the induced air grille and passes through the horizontal heat exchanger.

Primary and secondary airflows mix and are then supplied to the room horizontally through the supply air grille.

Nominal length

1000, 1125, 1250 mm

Length

1000, 1125, 1250 mm

Width

519, 616, 711, 808 mm

Height

207, 212 mm

Primary air spigot, diameter

123, 158 mm

Primary air volume flow rate

8 – 57 l/s or 29 – 205 m³/h

Cooling capacity

Up to 1600 W

Heating capacity

Up to 1000 W

Max. operating pressure, water side

10 bar (in combination with connection hoses 6 bar)

Max. operating temperature

75 °C (in combination with connection hoses 55 °C)


The quick sizing table contains operating points for defined reference units, whereby the data for devices without flow rate control subassemblies apply. For other operating points, you may use the Easy Product Finder design programme.



Reference values

Parameters Cooling
Heating

tR

26 °C

22 °C

tPr

16 °C

22 °C

tWV

16 °C

50 °C

VW

110 l/h

110 l/h


Active chilled beams of Type DID-E2, with oneway air discharge are a low-noise alternative to fan coil units, providing high thermal output and high thermal comfort levels.

For installation into ceiling bulkheads, preferably in rooms with a height up to 4.00 m.

The units consist of a casing with suspension points, a spigot, non-combustible nozzles, and a horizontal heat exchanger.

Five nozzle variants to optimise induction based on demand.

Special features

  • One-way air discharge
  • Horizontal heat exchanger as 2-pipe or 4-pipe system

  • The connection points are at the back of the unit, which is typically connected from the corridor

  • The supply air spigot is extendable to compensate for structural tolerances

  • Nominal sizes are based on the basic dimensions
  • Integral volume flow controller as an option

Materials and surfaces

  • Casing, nozzle plate, supply air spigot and installation subframe for secondary air grille made of galvanised sheet steel

  • Heat exchanger with copper tubes and aluminium fins

  • Surface of the casing and heat exchanger optionally available in black (RAL 9005)


Technical data

  • Nominal length: 1000, 1125, 1250 mm
  • Length: 1000, 1125, 1250 mm
  • Width: 519, 616, 711, 808 mm
  • Height: 207, 212 mm
  • Primary air spigot, diameter: 123, 158 mm
  • Primary air volume flow rate: 8 – 57 l/s or 29 – 205 m³/h

  • Cooling capacity: up to 1600 W
  • Heating capacity: up to 1000 W
  • Maximum operating pressure, water side: 10 bar (in combination with connection hoses 6 bar)

  • Maximum operating temperature: 75 °C (in combination with connection hoses 55 °C)


Sizing data

Primary air

  • V_____[m³/h]
  • Δpt_____[Pa]

Air-regenerated noise

  • LWA_____[dB(A)]

Cooling

  • Qges_____[W]

Heating

  • Qges_____[W]

This specification text describes the general properties of the product. Texts for variants can be generated with our Easy Product Finder design programme.

DID-E2-2-S1-R/1000x320x123

Heat exchanger

2-pipe

Nozzle variant

Medium

Arrangement of water connections

Right side

Nominal length x heat exchanger depth x primary air spigot

1000 × 320× 123


DID-E2-4-H2-L-A2/1250x512x158/VC/Z/ERS/G1

Heat exchanger

4-pipe

Nozzle variant

Nozzle mix (50 % S2 nozzle and 50 % HP nozzle)

Arrangement of water connections

Left side

Water connection

With union nut G½” and flat seal

Nominal length x heat exchanger depth x primary air spigot

1250 x 512 x 158

Volume flow control

With flow rate control subassembly

Supply air spigot

With extension spigot for supply air

Installation subframe for secondary air grille

Installation subframe for secondary air grille, including safety cables for the grille

Surface of casing and heat exchangerSurface of RAL 9005, jet black


KV-0,63/HV-0,4/R

Cooling valve

Cooling valve including actuator

kVS value – cooling valve

0,63

Heating valve

Heating valve including actuator

kVS value – heating valve

0,4

Lockshield(s)With

SL/925x525/VS

Secondary air grille

SL

Dimensions

925x525

Fixing

With concealed screw fixing

Surface of secondary air grille

RAL 9010


SL/925x125/VS/P1-RAL 9016

Supply air grille

SL

Dimensions

925x125

Fixing

VS: With concealed screw fixing

Surface of supply air

RAL 9016

Variants, Dimensions and weight

  • VARIANTS
  • DIMENSIONS AND WEIGHT

Dimensions [mm]

LN L K

1000

1000

940

1125

1125

1065

1250

1250

1190


Dimensions [mm]

BG
B

519

320

711

512



Dimensions [mm]

ØD

123

158


Weight (4L, 123, R+L) [kg]

Nominal length (LN)1000 x 3201000 x 5121125 x 320
1125 x 5121250 x 3201250 x 512

DID-E2

15,5

20,5

17,023,019,025,0

Supply air spigot Z

1,7

1,7

1,91,92,12,1

Installation subframe ERS

1,4

1,5

1,61,71,81,9

Contained water WÜ

1,52,51,83,02,13,5


Dimensions [mm]

BG
B

616

320

808

512


Weight (4L, 123, R+L) [kg]

Nominal length (LN)1000 x 3201000 x 5121125 x 320
1125 x 5121250 x 3201250 x 512

DID-E2-*-VC

21,5

26,524,029,526,032,0

Supply air spigot Z

1,7

1,71,91,92,12,1

Installation subframe ERS

1,4

1,51,61,71,81,9

Contained water WÜ

1,52,51,83,02,13,5


Installation details, Basic information and nomenclature

  • INSTALLATION DETAILS
  • BASIC INFORMATION AND NOMENCLATURE

Installation and commissioning

  • Preferably for rooms with a clear height up to 4.00 m

  • Installation into ceiling bulkheads
  • Side entry primary air spigot
  • Lengths to fit basic dimensions 1000, 1125 and 1250 mm

  • Heat exchanger depths 320 mm and 512 mm
  • Primary air spigot 123 mm and 158 mm
  • Installation and connections to be performed by others; fixing, connection and sealing material to be provided by others

  • Active chilled beam has 4 suspension points (slotted hole 38 x 8.5 mm) for on-site installation by others

  • Heat exchangers are fitted with water flow and water return connections at the rear, usually towards the corridor

  • With the optionally available supply air spigot, which works like a sliding spigot, installation areas of 38 – 78 mm are bridged

  • Secondary air can be suctioned through a grille from the TROX grille range, the perforated metal plate especially developed for the DIDE2 or through an opening or shadow gap provided by others

  • Secondary air grills must be secured with safety cables The optionally available installation subframe for secondary air grilles has safety cables that can be mounted on the grille

Nomenclature

LWA [dB(A)]

Sound power level

tPr [°C]

Primary air temperature

tWV [C°]

Water flow temperature – cooling/heating

tR [C°]

Room temperature

tAN [C°]

Secondary air intake temperature

QPr [W]

Thermal output – primary air

Qges [W]

Thermal output – total

QW [W]

Thermal output – water side, cooling/heating

VPr [l/s/m³/h]

Primary air volume flow rate

VW [l/h]

Water flow rate – cooling/heating

V [l/h]

Volume flow rate

∆tW [K]

Temperature difference – water

∆pW [kPa]

Water side pressure drop

∆pt [Pa]

Total pressure drop, air side

∆tPr = tPr - tR [K]

Difference between primary air temperature and room temperature

∆tRWV = tWV - tR [K]

Difference between water flow temperature and room temperature

∆tWm-Ref [K]

Difference between mean water temperature and reference temperature

Principal dimensions

LN [mm]

Nominal length

Mixed flow

The supply air is discharged from the air terminal device into the space with a velocity between 2 and 5 m/s. The resulting air jet mixes with the room air, ventilating the entire space. The mixed flow air distribution typically provides a uniform temperature distribution and air quality within the space. The originally high velocity of the turbulent air jets decreases rapidly due to the high induction levels of mixed flow air distribution systems.

Heat exchanger

The maximum water-side operating pressure for all heat exchangers is 10 bar. When flexible hoses are used, the maximum water-side operating pressure is limited to 6 bar.

The maximum water flow temperature (heating circuit) for all heat exchangers is 75 °C; if flexible hoses are used, the water flow temperature should not exceed 55 °C. Units for other pressures and temperatures are available on request.

The water flow temperature (cooling circuit) should be at least 16 °C such that it does not permanently fall below the dew point. For units with a condensate drip tray, the water flow temperature may be reduced to 15 °C.

Heat exchanger as 2-pipe system

Air-water systems with a 2-pipe heat exchanger may be used for either heating or cooling. In changeover mode, it is possible to use all units within a water circuit exclusively for cooling in summer and exclusively for heating in winter.

Heat exchanger as 4-pipe system

Air-water systems with a 4-pipe heat exchanger may be used for both heating and cooling. Depending on the season, i.e. especially in spring and autumn, it may be possible that an office has to be heated in the morning and cooled in the afternoon.

Stažení

informace o produktu

certifikáty

production {"X-Frame-Options"=>"SAMEORIGIN", "X-XSS-Protection"=>"1; mode=block", "X-Content-Type-Options"=>"nosniff", "X-Download-Options"=>"noopen", "X-Permitted-Cross-Domain-Policies"=>"none", "Referrer-Policy"=>"strict-origin-when-cross-origin", "Content-Security-Policy"=>"frame-ancestors 'self' https://api.scrivito.com https://punchoutcommerce.com https://www.trox.de https://trox-extern.com https://psp40.onventis.com https://psp22.onventis.com https://trox4u.troxgroup.com", "Strict-Transport-Security"=>"max-age=31536000; includeSubDomains", "Content-Type"=>"text/html; charset=utf-8"}

Sdílet stránku

Doporučit tuto stránku

Doporučit tuto stránku zasláním odkazu emailem.

Pole označená (*) jsou povinná.

Sdílet stránku

Děkujeme za doporučení!

Vaše doporučení bylo odesláno a zakrátko by mělo být doručeno.


Kontakt

Jsme tu pro vás

Uveďte prosím své sdělení a druh dotazu
Tel.: +420 283 880 380 | Fax: +420 286 881 870

Pole označená (*) jsou povinná.

Kontakt

Děkujeme vám za zprávu!

Vaše zpráva je odeslána a zakrátko bude zpracována.
Naše oddělení pro servisní dotazy se s vámi co nejrychleji spojí Pro obecné informace o výrobcích nebo o službách můžete také zavolat:
Tel.: +420 283 880 380 | Fax: +420 286 881 870

Kontakt

Jsme tu pro vás

Uveďte prosím své sdělení a druh dotazu
Tel.: +420 283 880 380 | Fax: +420 286 881 870

Attachment (max. 10MB)

Pole označená (*) jsou povinná.

Kontakt

Děkujeme vám za zprávu!

Vaše zpráva je odeslána a zakrátko bude zpracována.
Naše oddělení pro servisní dotazy se s vámi co nejrychleji spojí Pro obecné informace o výrobcích nebo o službách můžete také zavolat:
Tel.: +420 283 880 380 | Fax: +420 286 881 870